hello@crescenthealthcare.com.au
Browse more solutions
crescenthealthcare.com.au
55
CuroCell® A4 Cirrus is used as an aid in the prevention and treatment of pressure ulcers up to and including
category 4(1) and unclassified pressure ulcers/pressure injuries as well as an aid in pain therapy. It is a replacement
system suitable for all healthcare environments. CuroCell® A4 Cirrus combines air with a soft foam surface and
provides high user comfort and pressure redistribution(3). The combination of air and foam makes the system
suitable as an aid in pain therapy. The added heel function offers an even better pressure redistribution on the
heels.
The CuroCell® A4 Cirrus mattress system includes an intelligent control unit with a user-friendly interface. It is
fully automatic without need for manual settings. The system identifies the user and automatically manages
all settings to optimise the pressure according to the user’s needs. All mattresses are supplied with a four-way
stretch hygienic cover which meets standards for hygiene(4), quality and safety. All covers are manufactured from
modern, recyclable materials and are vapour permeable(5), which reduce the risk of skin maceration.
CuroCell®
A4 Cirrus
Features at a glance
•
Soft foam surface
•
Smart cable management
•
Easy handling and cleaning
•
Heel slope, for pressure redistribution of heels
•
Hygienic cover with welded seams
•
Soft, elastic, vapour permeable(5) hygienic
cover
•
Unique CPR-function with transport function
•
Fully automated control unit that adapts
individually
•
User-friendly interface
•
Audible and visual notifications
•
Three program modes: Pulsating, Alternating
and CLP (constant low pressure)
•
Caring mode (max-firm)
•
Pack&Go® function
•
Silent running and vibration free
•
Low voltage (12V power supply)
•
Soft friction hangers with extra soft tip
•
Air flow control; Constant temperature,
increased user comfort, energy reduction
•
Recommended user weight: 0-230kg
Ordering information
•
CR1889-80
800 x 2000 x 200mm
•
CR1889-85
850 x 2000 x 200mm
•
CR1889-90
900 x 2000 x 200mm
•
CR1889-100
1000 x 2000 x 200mm
•
CR1889-105
1050 x 2000 x 200mm
•
CR1889-120
1200 x 2000 x 200mm
References
(1) *Haesler, E. (Ed). National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance. (2014).
Prevention and Treatment of Pressure Ulcers: Clinical Guideline. Cambridge Media: Perth, Australia (2) EN ISO 11201 “Acoustics - Noise emitted by
machinery and equipment - Determination of emission sound pressure levels”, SP 2018. (3) Examination of the shear force and the pressure relief capability,
Berlin Cert 2009. (4) ISO 16603 “resistance of penetration by blood and body fluids”, ISO 16604 “resistance of penetration by blood-borne pathogens”,
EN 14126. (5) SS-EN ISO 15496:2004, DIN 53122-1. (6) ISO 3746:2010 “Acoustics - Determination of sound power levels and sound energy levels of noise
sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane”. (7) Dr Peter Worsley, Dr Luciana Bostan
and Professor Dan Bader. Investigation of the biomechanical and physiological responses to prolonged lying postures during three mattress modes.
Unpublished manuscript. University of Southampton, 2018. (8) Beeckman D., Van Hecke A., Verhaeghe S., Van Damme N., Manderlier B., Zwaenepoel E. The
use of a fully automated pulsating support system (CuroCell® A4 CX20) in pressure ulcer prevention and treatment: a clinical test in 10 Belgian nursing
homes, International Wound Journal. Gent University, 2019.
Prevention &
Treatment up to
Category
Max User
Weight
4+
230
kg