1300 04 05 06
26
CuroCell® IQ Cirrus is used as an aid in the prevention and treatment of pressure ulcers up to and including
category 4(1) and unclassified pressure ulcers/pressure injuries. It is a replacement system suitable for all
healthcare environments. CuroCell® IQ Cirrus combines air with a soft foam surface and provides high user
comfort and pressure redistribution(3). The combination of air and foam makes the system suitable as an aid in
pain therapy. The added heel function offers an even better pressure redistribution on the heels. The CuroCell® IQ
Cirrus identifies the user and automatically adapts itself to the individual. The control unit is preset to our newly
developed Pulsating mode, which offers a high level of comfort and effective pressure redistribution(7)(8).
All mattresses are supplied with a four-way stretch hygienic cover which meets standards for hygiene(4), quality
and safety. All covers are manufactured from modern, recyclable materials and are vapour permeable(5), which
reduce the risk of skin maceration.
Features at a glance
•
Soft foam surface
•
Smart cable management
•
Easy handling and cleaning
•
Heel slope, for pressure redistribution of heels
•
Hygienic cover with welded seams
•
Soft, elastic, vapour permeable(5) hygienic
cover
•
Unique CPR-function with transport function
•
Fully automated control unit that adapts
individually
•
User-friendly interface
•
Audible and visual notifications
•
Newly developed Pulsating mode
•
Caring mode (max-firm)
•
Pack&Go® function
•
Silent running and vibration free
•
Low voltage (12V power supply)
•
Soft friction hangers with extra soft tip
•
Air flow control; Constant temperature,
increased user comfort, energy reduction
•
Recommended user weight: 0-230kg
References
(1) *Haesler, E. (Ed). National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance. (2014).
Prevention and Treatment of Pressure Ulcers: Clinical Guideline. Cambridge Media: Perth, Australia (2) EN ISO 11201 “Acoustics - Noise emitted by
machinery and equipment - Determination of emission sound pressure levels”, SP 2018. (3) Examination of the shear force and the pressure relief
capability, Berlin Cert 2009. (4) ISO 16603 “resistance of penetration by blood and body fluids”, ISO 16604 “resistance of penetration by blood-borne
pathogens”, EN 14126. (5) SS-EN ISO 15496:2004, DIN 53122-1. (6) ISO 3746:2010 ”Acoustics - Determination of sound power levels and sound energy
levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane”. (7) Dr Peter Worsley,
Dr Luciana Bostan and Professor Dan Bader. Investigation of the biomechanical and physiological responses to prolonged lying postures during three
mattress modes. Unpublished manuscript. University of Southampton, 2018. (8) Beeckman D., Van Hecke A., Verhaeghe S., Van Damme N., Manderlier B.,
Zwaenepoel E. The use of a fully automated pulsating support system (CuroCell® A4 CX20) in pressure ulcer prevention and treatment: a clinical test in
10 Belgian nursing homes, International Wound Journal. Gent University, 2019.
Ordering information
•
CR1970-80
800 x 2000 x 200mm
•
CR1970-85
850 x 2000 x 200mm
•
CR1970-90
900 x 2000 x 200mm
•
CR1970-100
1000 x 2000 x 200mm
•
CR1970-105
1050 x 2000 x 200mm
•
CR1970-120
1200 x 2000 x 200mm
CuroCell® IQ Cirrus
Prevention &
Treatment up to
Category
Max User
Weight
4+
230
kg