Image 3 - Washable Bed

Washable universal bed: low height and excellent design

Image 3 W

2

LINET | Image 3 W

Simply the best for your hospital department

LINET | Image 3 W

3

Summary of the beneÞ ts:

• 3 Stop Strategy and SafeFree® siderails as

patented side protection concept contribute

to fall prevention and actively support

patient mobilisation. The programmed

position for washing ensures that the

Image 3 W bed has the right height for

whatever standard washing machine for

beds – even with accessories such as lifting

pole or IV pole.

• Centrally braked 4 castors with 5th castor

ensure top mobility and manoeuvrability

even in very narrow spaces.

• Unique Ergomframe® system helps to

effective prevention of pressure ulcers.

• As universal hospital bed, Image 3 washable

can be used in different departments.

• Bed adjustment is easy and simple.

• The hotel design creates an attractive

environment for quick recovery and ensures

a cosy atmosphere in the room. The intuitive

contours and symbols on the control

features make handling simpler.

• The special frame is suitable for mechanical

disinfection, makes cleaning and drying

easier.

• Image 3 W is made of quality

corrosive-resistant materials such as

stainless steel, aluminium, HPL and KTL

(catalytic coating).

Working group for

decontamination systems of

bed frames

AK-

BWA

LINET | Image 3 W

5

ß

The Image 3 W bed is designed for all standard washing tunels. It has been tested in such facili-

ties as Miele, Dirschl, MMM, Kleindienst and Belimed. The ß exible frame guarantees the Image 3 W

bed’s compatibility with various track systems.

Ready to be cleaned mechanically

Designed for cleaning in automatic hospital washing machine

Best preconditions for effective processes

• Corrosive-resistant materials, electronics protected for use in IPX6 washing tunels

• Sophisticated frame with ideally placed drainage holes

• Release of the mattress platform with the aid of Easy-Click laminate for perfect drying results

• Suitable for mechanical washing according to AK-BWA

• The smooth and large areas ensure quick drainage with no collection of water

• Programmed position for washing can be set at the press of one button. Therefore even beds

with a lifting pole and IV pole can be simply and quickly prepared for steering through a door and

transport by lift.

Suitable for mechanical washing

according to AK-BWA

14

10

38

30

22

6

LINET | Image 3 W

Result: 70% more cleaning of beds a year

Comfortable transport

Current trends set the strictest requirements…

...for effective transport and cleaning

Annually 65,000 bedridden patients

are moved at a department with ca.

1,100 beds. But staff cover more than

10,000 km. But this leads to typical

problems: turning the bed in the pa-

tient’s room, manoeuvring in narrow

turns and into lifts.

„5th castor“

To meet the current requirements of

departments and making daily nursing

care easier, the Image 3 W bed has the

innovative 5th castor. This castor makes

the bed’s transport with or without a

patient considerably easier and can be

done by just one person. Thus effective

transport is much greater than in the

central locking of the 4 castors with the

guide castor and considerably facilitates

the bed’s logistics.

*Example: St. Pölten University of Applied Sciences, 2014

Data source: Federal Statistical OfÞ ce, key hospital data in. 2013

Data source: Federal Statistical OfÞ ce, key hospital data in. 2013

Average time of stay

Annual cleaning per bed a year

Time of stay at department since 1991

has almost halved

2012

37 days

1991

22 days

2012

7,6 days

1991

14 days

1991 1994 1997 2000 2003 2006 2009 2012

1991 1994 1997 2000 2003 2006 2009 2012

14

10

38

30

22

LINET | Image 3 W

7

The 5th castor is located centrally between the

four main castors and makes problem-free ma-

noeuvring in narrow corridors, small rooms and

when turning the bed in one spot possible. It sup-

ports the bed’s stable straight direction along

long corridors and makes it considerably easier

to steer the bed into and out of a lift.

• 4 castor centrally braked (standard)

• Double castors (optional)

• Acustic Brake Alarm (optional)

In a patient’s room

Further effective transport solution

On corridors

In lifts

5th castor: unexpected easy way

• Easy turning on the spot

• No swerving when turning a corner

• Safe steering thanks to the 5th castor

and the pre-programmed washing position

The Image 3 W bed has a whole number of

innovative and useful accessories for trans-

port and safety.

8

LINET | Image 3 W

Split SafeFree® siderails can be adjusted to the

4 different height levels and perfectly Þ ts to spe-

ciÞ c request on patient’s treatment. Variability

has multiple ways of use – SafeFree® siderails

provide feeling of safety to the patient, protect

him, help when standing up and not restraining

him at the same time.

1. no protection, full freedom of movement

(4 sides lowered)

2. minimum height provides orientation,

no restriction (3 sides at level 2)

3. ¾ protection without FEM* (3 sides

at level 3 or 4)

4. full protection (4 sides at level 3 or 4)

Patented SafeFree® side protection concept

Split telescopic SafeFree® siderails deals with patient’s safety and the individual needs

in a unique way. It provides maximum protection without restrictions.

SafeFree® siderails

Patented concept of securing sides for safety mobilisation

Full length SafeFree® siderails provides 100%

safety. None additional accessories in between or

at foot end are requested. There aren’t any dan-

gerous gaps or pinch points among siderails and

bed ends.

SafeFree® siderails are telescopic and don’t re-

quest any additional space beside the bed and it

can be used also in narrow places. It allows to use

bedside cabinet closely to the bed.

LINET | Image 3 W

9

Smart details: integrated mobilisation han-

dle for better standing up, double locking

mechanism and simple height adjustment of

SafeFree® siderails.

* FEM = Freiheitsentziehende Maßnahme

The sophisticated safety concept – double

locking mechanism rules out accidental lowering

of the sides, such as during mobilisation.

Maximum height of SafeFree® siderails of 40 cm

perfectly protect patients while using high

active air mattresses up to 18 cm height. Active

mattress Precioso is recommended to be used.